Contrinex堪泰
-
DW-AD-613-C60 Application TypeStandard Rated operating distance sn50 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 65...
[2016-03-07] -
DW-AD-613-C40 Application TypeStandard Rated operating distance sn40 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 65...
[2016-03-07] -
DW-AD-611-M30-120 Application TypeStandard Rated operating distance sn15 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC P...
[2016-03-07] -
DW-AD-611-M30 Application TypeStandard Rated operating distance sn15 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permi...
[2016-03-07] -
DW-AD-611-M18-120 Rated operating distance sn8 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permissible rippl...
[2016-03-07] -
DW-AD-611-M18 Application TypeStandard Rated operating distance sn8 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...
[2016-03-07] -
DW-AD-611-M12-120 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Pe...
[2016-03-07] -
DW-AD-611-M12 Application TypeStandard Rated operating distance sn4 mm MountingNon-embeddable Hysteresis< 20 % sr Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30 VDC Permis...
[2016-03-07] -
DW-AD-611-M8-122 Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...
[2016-03-07] -
DW-AD-611-M8-121 Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 ...
[2016-03-07] -
DW-AD-611-M8 Application TypeStandard Rated operating distance sn2.5 mm MountingNon-embeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB10 … 30...
[2016-03-07] -
DW-AD-608-M30 Application TypeStandard Rated operating distance sn10 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VA...
[2016-03-07] -
DW-AD-608-M18 Application TypeStandard Rated operating distance sn5 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VAC...
[2016-03-07] -
DW-AD-608-M12 Application TypeStandard Rated operating distance sn2 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VAC...
[2016-03-07] -
DW-AD-607-M30 Application TypeStandard Rated operating distance sn10 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VA...
[2016-03-07] -
DW-AD-607-M18 Application TypeStandard Rated operating distance sn5 mm MountingEmbeddable Hysteresis≤ 20 % sr (10 % typ.) Repeat accuracy norm≤ 5 % sr Supply voltage range UB20 … 265 VAC...
[2016-03-07]