AF16-30-22-13 / 1SBL177001R1322模塊化接觸器100-250V50/60HZ-DC Contactor,如需訂購該ABB產品請咨詢上海銳譽實業有限公司
概要信息
Extended Product Type:
AF16-30-22-13
Product ID:
1SBL177001R1322
Catalog Description:
AF16-30-22-13 100-250V50/60HZ-DC Contactor
Long Description:
AF16 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block, side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Note: 2-stack contactors available in some countries: please consult your ABB representative.
分類
產品? - 低壓產品及系統
? - 控制產品
? - 接觸器
? - 模塊化接觸器
Ordering
Dimensions
Container Information
Package Level 1 Gross Weight:
Environmental
Ambient Air Temperature:
Close to Contactor for Storage -60...+80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Maximum Operating Altitude Permissible:
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Resistance to Vibrations acc. to IEC 60068-2-6:
5...300 Hz 4 g closed position / 2 g open position
RoHS Status:
Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
Technical
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240V) 4 kW
(380 / 400V) 7.5 kW
(415V) 9 kW
(440V) 9 kW
(500V) 9 kW
(690V) 9 kW
Rated Operational Current AC-1 (Ie):
(690V) 40°C 30 A
(690V) 60°C 30 A
(690V) 70°C 26 A
Number of Main Contacts NO:
Number of Main Contacts NC:
Number of Auxiliary Contacts NO:
Number of Auxiliary Contacts NC:
Rated Control Circuit Voltage (Uc):
50 Hz 100...250 V
60 Hz 100...250 V
DC Operation 100...250 V
Technical UL/CSA
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Certificates and Declarations (Document Number)
Declaration of Conformity - CE:
GOST Certificate:
GOST_POCCFR.ME77.B07175.pdf
Classifications
1SBL177501R1300 AF16-22-00-13
1SBL177501R1400 AF16-22-00-14
1SBL177001R1122 AF16-30-22-11
1SBL177001R1222 AF16-30-22-12
1SBL177001R1322 AF16-30-22-13
1SBL177001R1422 AF16-30-22-14
1SBL156001R2022 AF12Z-30-22-20
1SBL156001R2122 AF12Z-30-22-21
1SBL156001R2222 AF12Z-30-22-22
1SBL156001R2322 AF12Z-30-22-23
1SBL237001R1100 AF26-30-00-11
1SBL237001R1200 AF26-30-00-12
1SBL237001R1300 AF26-30-00-13
1SBL237001R1400 AF26-30-00-14
1SBL237001R1111 AF26-30-11-11
1SBL237001R1211 AF26-30-11-12
1SBL237001R1311 AF26-30-11-13
1SBL237001R1411 AF26-30-11-14
1SBL176001R2001 AF16Z-30-01-20
1SBL176001R2101 AF16Z-30-01-21
1SBL176001R2201 AF16Z-30-01-22
1SBL176001R2301 AF16Z-30-01-23
1SBL176001R2010 AF16Z-30-10-20
1SBL176001R2110 AF16Z-30-10-21
1SBL176001R2210 AF16Z-30-10-22
1SBL176001R2310 AF16Z-30-10-23
1SBL237201R1100 AF26-40-00-11
1SBL237201R1200 AF26-40-00-12
1SBL237201R1300 AF26-40-00-13